The CCG E1W Cable Gland Kit is a trusted solution for terminating steel wire armoured (SWA)cables in industrial indoor, outdoor installations. Precision machined from extruded nickel-plated brass, this gland maintains a secure connection even in harsh weather or wet conditions.

The four-part design prevents twisting of the armour, while the inner polychloroprene seal blocks water ingress from under the armour wire.  Dust and ingress protection to IP66 and IP68 standards when installed with supplied sealing washer. This ensures electrical continuity and strain relief on power and control cables.

Each kit up to M32 includes two glands, two locknuts, two earth tags and two PVC shrouds. M40 and larger come as single kits with locknut and shroud.

Ideal for panels, junction boxes and exposed SWA runs where durability and safety matter most.

 

Key Features

  • Designed for SWA cable terminations in outdoor or exposed environments
  • IP66 and IP68 rated with sealing washer
  • Maintains electrical earth continuity through armour
  • Freely rotating captive cone, providing an armour clamp and earth bond without twisting the armouring
  • Two-part handling, no loose parts
  • Patented disconnect armour clamp system for ease of inspection
  • M16-M32 2 glands, 2 locknuts, 2 earth tags, 2 sealing washers, 2 PVC shrouds
  • M40-M100 1 gland, 1 locknut, 1 earth tag, 1 sealing washer, 1 PVC shroud

 

Technical Details

Design Standards: BS 6121 Part 1 EN 50262 IEC/BS EN 62444 SANS 62444 SANS 1213
Installation: AS/NZS 3000 BS 7430 BS 6121-5 IEC 60364-5-54
Protection: IP66 / IP68 (100m - Parallel) IEC 60529
Marine: ABS IEC 60529, IEC 62444, DNV IEC 60529, BS 6121, IEC 62444
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Seal): Thermoset Elastomer

 

Quick Links

E1W Kits
3 - 32
Silver
1.60
26.5
26.5
33.5
10.0
47.0
42.0
1.60
2.0
70
19.0

Built To Order

0

£43.25 Excl VAT
Unit Price: £43.2500
£51.90 Inc VAT
Unit Price: £51.9000

This product is currently out of stock. Your item will be shipped when it is back in stock.

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The CCG E1W Cable Gland Kit is a trusted solution for terminating steel wire armoured (SWA)cables in industrial indoor, outdoor installations. Precision machined from extruded nickel-plated brass, this gland maintains a secure connection even in harsh weather or wet conditions.

The four-part design prevents twisting of the armour, while the inner polychloroprene seal blocks water ingress from under the armour wire.  Dust and ingress protection to IP66 and IP68 standards when installed with supplied sealing washer. This ensures electrical continuity and strain relief on power and control cables.

Each kit up to M32 includes two glands, two locknuts, two earth tags and two PVC shrouds. M40 and larger come as single kits with locknut and shroud.

Ideal for panels, junction boxes and exposed SWA runs where durability and safety matter most.

 

Key Features

  • Designed for SWA cable terminations in outdoor or exposed environments
  • IP66 and IP68 rated with sealing washer
  • Maintains electrical earth continuity through armour
  • Freely rotating captive cone, providing an armour clamp and earth bond without twisting the armouring
  • Two-part handling, no loose parts
  • Patented disconnect armour clamp system for ease of inspection
  • M16-M32 2 glands, 2 locknuts, 2 earth tags, 2 sealing washers, 2 PVC shrouds
  • M40-M100 1 gland, 1 locknut, 1 earth tag, 1 sealing washer, 1 PVC shroud

 

Technical Details

Design Standards: BS 6121 Part 1 EN 50262 IEC/BS EN 62444 SANS 62444 SANS 1213
Installation: AS/NZS 3000 BS 7430 BS 6121-5 IEC 60364-5-54
Protection: IP66 / IP68 (100m - Parallel) IEC 60529
Marine: ABS IEC 60529, IEC 62444, DNV IEC 60529, BS 6121, IEC 62444
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Seal): Thermoset Elastomer

 

Information

Product Type: E1W Kits

Size: 3 - 32

Colour: Silver

Entry Thread Size: 1.60

Bedding OD Max (A): 26.5

Cable OD Range Min (B): 26.5

Cable OD Range Max (B): 33.5

Gland Length (L2): 10.0

A/C: 47.0

A/F: 42.0

Armour Dia Min (F): 1.60

Armour Dia Max (F): 2.0

Torque (Nm): 70

Bedding OD Min (A): 19.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 