Electrical Safety Matting is specifically engineered to provide critical shock protection for personnel working in high-voltage environments. It is commonly deployed in front of open switchboards, control panels, and distribution sub-stations. Manufactured from a premium natural elastomer, this high grade matting features a specialised fine ribbed surface on one side, which delivers exceptional anti-slip properties to ensure maximum traction and worker safety.

This halogen free matting is designed to endure demanding industrial conditions while maintaining its high dielectric integrity. To provide ultimate flexibility for your facility layout, we offer the matting in complete 10 meter continuous rolls or cut-to-order by the linear meter. Because of the heavy duty nature and significant weight of this safety product, please note that certain custom lengths cannot be dispatched via standard courier networks, and a palletised delivery charge may apply.


 

Key Features

  • Working Voltage – 1,000 volts / 1kV.
  • Matting Thickness 6mm
  • Withstand Test – 10kV – No Electrical Puncture
  • Cut lengths of mats available to order
  • Mechanical Puncher Resistance - 70n
  • Anti-slip finish
  • Halogen free
  • Sold in 10m metre rolls or by the linear metre
  • Due to product weight certain lengths cannot be sent with couriers so a pallet charge may be applicable

 

 

Technical Details

Working Voltage:   1,000 volts / 1kV.
Withstand Test:  10kV

Material: Natural Elastomer
Colour: Black

 

Quick Links

Black
914.0
6.0
10
75.0

In stock

2

£36.43 Excl VAT
Unit Price: £36.4300
£43.72 Inc VAT
Unit Price: £43.7160

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

Electrical Safety Matting is specifically engineered to provide critical shock protection for personnel working in high-voltage environments. It is commonly deployed in front of open switchboards, control panels, and distribution sub-stations. Manufactured from a premium natural elastomer, this high grade matting features a specialised fine ribbed surface on one side, which delivers exceptional anti-slip properties to ensure maximum traction and worker safety.

This halogen free matting is designed to endure demanding industrial conditions while maintaining its high dielectric integrity. To provide ultimate flexibility for your facility layout, we offer the matting in complete 10 meter continuous rolls or cut-to-order by the linear meter. Because of the heavy duty nature and significant weight of this safety product, please note that certain custom lengths cannot be dispatched via standard courier networks, and a palletised delivery charge may apply.


 

Key Features

  • Working Voltage – 1,000 volts / 1kV.
  • Matting Thickness 6mm
  • Withstand Test – 10kV – No Electrical Puncture
  • Cut lengths of mats available to order
  • Mechanical Puncher Resistance - 70n
  • Anti-slip finish
  • Halogen free
  • Sold in 10m metre rolls or by the linear metre
  • Due to product weight certain lengths cannot be sent with couriers so a pallet charge may be applicable

 

 

Technical Details

Working Voltage:   1,000 volts / 1kV.
Withstand Test:  10kV

Material: Natural Elastomer
Colour: Black

 

Information

Colour: Black

Width (W): 914.0

Supplied Thickness: 6.0

Roll Size (m): 10

Roll Weight (Kg): 75.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 