The GripLoc Ex Nylon Cable Gland are designed for safe, certified cable termination in hazardous areas. It's fully compliant with ATEX and IECEx standards for Exe (Increased Safety) applications, making it suitable for use in Zone 1 and Zone 2 gas environments, as well as Zone 21 and Zone 22 dust atmospheres.
GripLoc EX cable glands are designed for use in explosive atmospheres with unarmoured or braided cables that are terminated within the enclosure. Suitable for extreme conditions, it offers a wide operating temperature range from -20°C to +80°C.
Manufactured from flame-retardant PA6 nylon, it offers watertight IP68 protection against water, dust and environmental stress. The design includes built-in Vibration-Lock to prevent loosening over time, and Friction Splines to give a tool-friendly, slip-resistant grip during installation.

The internal Ridge-and-Groove structure delivers dependable strain relief and helps stabilise the cable under tension or flex. A wide clamping range covers multiple cable sizes, reducing stock requirements and simplifying setup. GripLoc Exe is a smart, reliable solution for control panels, junction boxes and equipment installed in hazardous areas.



 

Key Features

  • ATEX & IECEx certified for Exe increased safety applications
  • IP68 rated for high ingress protection
  • Made from flame-retardant PA6 nylon
  • Vibration-Lock keeps the gland securely fitted over time
  • Friction Splines ensure better handling and torque control
  • Ridge-and-Groove structure improves strain relief
  • Wide clamping range supports flexible sizing
  • Supplied Complete with 'O'ring seal and locknuts


 

Technical Details

Material:  Polyamide
Seal: Neoprene
Protection Degree: IP66 / IP68 without thread sealing
Type of Protection: Ex e ATEX / EICEx
Conformity with standards: EN 60079-0, EN 60079-7, EN 60079-31
Device Group: ll Category: 2 and 3
Atmosphere: G / D Zone: 1, 2 Zone: 21, 22 with flatseal
Temperature: -20°C to +80°C


 

Quick Links

GripLoc-EX Black
Black
M12 x 1.5
3.0
6.5
8.0
29.0
15.0

In stock

2110

£12.10 Excl VAT
Unit Price: £1.2100
£14.52 Inc VAT
Unit Price: £1.4520

Qty
Minimum Order Qty 10
Increments 10

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The GripLoc Ex Nylon Cable Gland are designed for safe, certified cable termination in hazardous areas. It's fully compliant with ATEX and IECEx standards for Exe (Increased Safety) applications, making it suitable for use in Zone 1 and Zone 2 gas environments, as well as Zone 21 and Zone 22 dust atmospheres.
GripLoc EX cable glands are designed for use in explosive atmospheres with unarmoured or braided cables that are terminated within the enclosure. Suitable for extreme conditions, it offers a wide operating temperature range from -20°C to +80°C.
Manufactured from flame-retardant PA6 nylon, it offers watertight IP68 protection against water, dust and environmental stress. The design includes built-in Vibration-Lock to prevent loosening over time, and Friction Splines to give a tool-friendly, slip-resistant grip during installation.

The internal Ridge-and-Groove structure delivers dependable strain relief and helps stabilise the cable under tension or flex. A wide clamping range covers multiple cable sizes, reducing stock requirements and simplifying setup. GripLoc Exe is a smart, reliable solution for control panels, junction boxes and equipment installed in hazardous areas.



 

Key Features

  • ATEX & IECEx certified for Exe increased safety applications
  • IP68 rated for high ingress protection
  • Made from flame-retardant PA6 nylon
  • Vibration-Lock keeps the gland securely fitted over time
  • Friction Splines ensure better handling and torque control
  • Ridge-and-Groove structure improves strain relief
  • Wide clamping range supports flexible sizing
  • Supplied Complete with 'O'ring seal and locknuts


 

Technical Details

Material:  Polyamide
Seal: Neoprene
Protection Degree: IP66 / IP68 without thread sealing
Type of Protection: Ex e ATEX / EICEx
Conformity with standards: EN 60079-0, EN 60079-7, EN 60079-31
Device Group: ll Category: 2 and 3
Atmosphere: G / D Zone: 1, 2 Zone: 21, 22 with flatseal
Temperature: -20°C to +80°C


 

Information

Product Type: GripLoc-EX Black

Colour: Black

Entry Thread Size: M12 x 1.5

Cable OD Range Min (B): 3.0

Cable OD Range Max (B): 6.5

Entry Thread Length (L1): 8.0

Gland Length (L2): 29.0

A/F: 15.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?


If you have spotted a mistake on this page, click the button below and complete the form. Thank you!

Report mistake

 
 

Related products