Tablet

Mobile

Inc VAT Ex VAT

First time logging in? Please click 'Forgotten your password?', input your existing registered email address and set your new password.

 
 

SKU: GripLoc-EX-M50-BL

GRIPLOC-EX-M50-BL - M50 EExe Nylon Cable Gland - Blue

SKU: GripLoc-EX-M50-BL

GRIPLOC-EX-M50-BL - M50 EExe Nylon Cable Gland - Blue

GripLoc® Ex i Nylon Cable Glands are designed to meet the strict safety requirements for intrinsically safe installations in hazardous areas. With a blue body for clear Ex i identification, these glands ensure quick visual compliance across Zone 1, Zone 2 (gas) and Zone 21, Zone 22 (dust) environments.

Made from flame-retardant PA6 nylon, they provide a secure, watertight seal up to IP68, helping protect connections from dust, water and vibration. A wide clamping range covers multiple cable sizes, reducing stock variation and making planning simpler on-site.

The internal Ridge-and-Groove design helps stabilise the cable under tension or movement. Vibration-Lock technology keeps the gland in place, even under long-term use. Friction Splines give added grip and torque control during installation.

Tested and certified to ATEX and IECEx for Ex e use, GripLoc® Ex i glands are a dependable option for control panels, junction boxes and other enclosures where safety and integrity matter most.

Whether it's offshore, processing plants, or general hazardous area equipment, these glands provide protection you can trust, backed by clear blue Ex i identification for fast, confident inspection.


 

Key Features

  • ATEX & IECEx certified for Exe increased safety applications
  • IP68 rated for high ingress protection
  • Made from flame-retardant PA6 nylon
  • Vibration-Lock keeps the gland securely fitted over time
  • Friction Splines ensure better handling and torque control
  • Ridge-and-Groove structure improves strain relief
  • Wide clamping range supports flexible sizing
  • Supplied Complete with 'O'ring seal and locknuts


 

Technical Details

Material:  Polyamide
Seal: Neoprene
Protection Degree: IP66 / IP68 without thread sealing
Type of Protection: Ex e ATEX / EICEx
Conformity with standards: EN 60079-0, EN 60079-7, EN 60079-31
Device Group: ll Category: 2 and 3
Atmosphere: G / D Zone: 1, 2 Zone: 21, 22 with flatseal
Temperature: -20°C to +80°C


Quick Links

GripLoc-EX Blue
Blue
M50 x 1.5
32.0
38.0
13.0
62.0
60.0

In stock

102

£7.45 Excl VAT
Unit Price: £7.4500
£8.94 Inc VAT
Unit Price: £8.9400

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

GripLoc® Ex i Nylon Cable Glands are designed to meet the strict safety requirements for intrinsically safe installations in hazardous areas. With a blue body for clear Ex i identification, these glands ensure quick visual compliance across Zone 1, Zone 2 (gas) and Zone 21, Zone 22 (dust) environments.

Made from flame-retardant PA6 nylon, they provide a secure, watertight seal up to IP68, helping protect connections from dust, water and vibration. A wide clamping range covers multiple cable sizes, reducing stock variation and making planning simpler on-site.

The internal Ridge-and-Groove design helps stabilise the cable under tension or movement. Vibration-Lock technology keeps the gland in place, even under long-term use. Friction Splines give added grip and torque control during installation.

Tested and certified to ATEX and IECEx for Ex e use, GripLoc® Ex i glands are a dependable option for control panels, junction boxes and other enclosures where safety and integrity matter most.

Whether it's offshore, processing plants, or general hazardous area equipment, these glands provide protection you can trust, backed by clear blue Ex i identification for fast, confident inspection.


 

Key Features

  • ATEX & IECEx certified for Exe increased safety applications
  • IP68 rated for high ingress protection
  • Made from flame-retardant PA6 nylon
  • Vibration-Lock keeps the gland securely fitted over time
  • Friction Splines ensure better handling and torque control
  • Ridge-and-Groove structure improves strain relief
  • Wide clamping range supports flexible sizing
  • Supplied Complete with 'O'ring seal and locknuts


 

Technical Details

Material:  Polyamide
Seal: Neoprene
Protection Degree: IP66 / IP68 without thread sealing
Type of Protection: Ex e ATEX / EICEx
Conformity with standards: EN 60079-0, EN 60079-7, EN 60079-31
Device Group: ll Category: 2 and 3
Atmosphere: G / D Zone: 1, 2 Zone: 21, 22 with flatseal
Temperature: -20°C to +80°C


Information

Product Type: GripLoc-EX Blue

Colour: Blue

Entry Thread Size: M50 x 1.5

Cable OD Range Min (B): 32.0

Cable OD Range Max (B): 38.0

Entry Thread Length (L1): 13.0

Gland Length (L2): 62.0

A/F: 60.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?