The CCG IPlus Corrosion Guard Cable Gland is engineered to provide safe, durable terminations for armoured cables in harsh environments. This gland is ideal for outdoor or industrial applications where moisture, dust, and corrosion pose a constant threat.
Built from high-quality brass and finished with CCG's IPlus Corrosion Guard it offers long-lasting protection against aggressive chemicals, salt air, and weathering. The gland ensures a strong mechanical grip on armoured cables while sealing the inner & outer sheath to maintain IP68 rated ingress protection.
The gland delivers everything needed for fast, secure installations. Its robust design maintains performance under vibration and temperature variation, making it suitable for power distribution panels, junction boxes, and field equipment.
The IPlus Corrosion Guard Cable Gland is a practical solution for keeping armoured cable terminations secure, corrosion-resistant, and electrically safe in the most demanding conditions.

 

Key Features

  • For highly corrosive and wet locations
  • Three-part handling, no loose parts
  • The screw-on Corrosion Guard™ is manufactured from non-corrosive material to protect the armour and metal parts of the gland
  • Factory fitted captive elastomeric inner seal for Built In Safety™
  • Seals on both the inner and outer sheath to IP66 / IP6
  • Supplied complete with IP sealing washer

 

Technial Details

Design Standards:BS 6121 Part 1 EN 50262 IEC/BS EN 62444 SANS 62444 SANS 1213
Protection: IP66 / IP68 (100m - Parallel) IEC 60529
Marine: ABS IEC 62444, DNV IEC 60529, BS 6121, IEC 62444
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Shroud): Glass Reinforced Polyester / PBT
Material (Seal): Thermoset Elastomer

 

Quick Links

IPlus Glands
6 - 63
Grey
M63 x 1.5
56.5
52.5
65.5
15.0
137.0
90.0
80.0
2.00
2.5
120
44.0
110.0

Out of Stock - Back Order

0

£94.56 Excl VAT
Unit Price: £94.5600
£113.47 Inc VAT
Unit Price: £113.4720

This product is currently out of stock. Your item will be shipped when it is back in stock.

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

 

The CCG IPlus Corrosion Guard Cable Gland is engineered to provide safe, durable terminations for armoured cables in harsh environments. This gland is ideal for outdoor or industrial applications where moisture, dust, and corrosion pose a constant threat.
Built from high-quality brass and finished with CCG's IPlus Corrosion Guard it offers long-lasting protection against aggressive chemicals, salt air, and weathering. The gland ensures a strong mechanical grip on armoured cables while sealing the inner & outer sheath to maintain IP68 rated ingress protection.
The gland delivers everything needed for fast, secure installations. Its robust design maintains performance under vibration and temperature variation, making it suitable for power distribution panels, junction boxes, and field equipment.
The IPlus Corrosion Guard Cable Gland is a practical solution for keeping armoured cable terminations secure, corrosion-resistant, and electrically safe in the most demanding conditions.

 

Key Features

  • For highly corrosive and wet locations
  • Three-part handling, no loose parts
  • The screw-on Corrosion Guard™ is manufactured from non-corrosive material to protect the armour and metal parts of the gland
  • Factory fitted captive elastomeric inner seal for Built In Safety™
  • Seals on both the inner and outer sheath to IP66 / IP6
  • Supplied complete with IP sealing washer

 

Technial Details

Design Standards:BS 6121 Part 1 EN 50262 IEC/BS EN 62444 SANS 62444 SANS 1213
Protection: IP66 / IP68 (100m - Parallel) IEC 60529
Marine: ABS IEC 62444, DNV IEC 60529, BS 6121, IEC 62444
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Shroud): Glass Reinforced Polyester / PBT
Material (Seal): Thermoset Elastomer

 

Information

Product Type: IPlus Glands

Size: 6 - 63

Colour: Grey

Entry Thread Size: M63 x 1.5

Bedding OD Max (A): 56.5

Cable OD Range Min (B): 52.5

Cable OD Range Max (B): 65.5

Entry Thread Length (L1): 15.0

Gland Length (L2): 137.0

A/C: 90.0

A/F: 80.0

Armour Dia Min (F): 2.00

Armour Dia Max (F): 2.5

Torque (Nm): 120

Bedding OD Min (A): 44.0

Overall Dia (G): 110.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?