Tablet

Mobile

Inc VAT Ex VAT

First time logging in? Please click 'Forgotten your password?', input your existing registered email address and set your new password.

 
 

SKU: 052716A

052716A - M16 FLP-Hose ATEX Group 1 Group 2 Gland

SKU: 052716A

052716A - M16 FLP-Hose ATEX Group 1 Group 2 Gland

The FLP Hose Compression Gland is built for flame-proof cable terminations in demanding industrial & underground mining locations. Designed for unarmoured elastomeric and plastic cables, it provides a tight seal to prevent gas or flame migration that is suitable for use in Group I underground mines, Group II, III, Zone 1, 2, 21 and 22 hazardous areas.
The male spigot at the rear allows you to securely attach a flexible protective hose, adding extra shielding for cables exposed to harsh conditions. Precision manufactured from high-quality extruded brass, Marine Grade Electroless Nickel Plated™, this gland offers high resistance to impact, moisture and corrosive atmospheres. Suitable for hazardous areas where flame containment and secure sealing are critical.

 

Key Features

  • For Group I underground mines, Group II, III, Zone 1, 2, 21 and 22 hazardous areas
  • Fitted complete with a specially formulated elastomeric captive seal for Built-in Safety™
  • A hose tail provides for clamping a protective hose over the cable
  • Precision manufactured from extruded brass, Marine Grade Electroless Nickel Plated™
  • Supplied complete with IP sealing washer

 

Technical Details

Equipment Protection Levels:  
IECEx/INMETRO:                Ex db I Mb / Ex eb I Mb / Ex db IIC Gb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da
ATEX/UKEX:                        I M2, II 2/3G 1D, Ex db I Mb / Ex eb I Mb / Ex db IIC Gb / Ex eb IIC Gb, Ex nR IIC Gc,
                                            Ex ta  IIIC Da

Conformance:               Standard:                                       Certification:
IEC/BS EN                     IEC/BS EN 62444, 6121               CML 14CA364 
IECEx                             IEC 60079 Part 0, 1, 7, 15, 31      IECEx TSA 22.0011X
ATEX                              EN 60079 Part 0, 1, 7, 31             CML 16ATEX1001X
                                       EN 60079 Part 0, 15                     CML 16ATEX4002X
UKEX                             BS EN 60079 Part 0, 1, 7, 31        CML 21UKEX1011X
                                      BS EN 60079 Part 0, 15                 CML 21UKEX4006X
Deluge Protection:        DTS-01
Marine:            ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
                         DNV IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
Protection:     IP66 / IP68 (100m - Parallel)  IEC 60529
Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
Material (Gland):  Brass, Marine Grade Electroless Nickel Plated™
Material (Seal):   Standard Thermoset Elastomer or Extreme Temperature Seals

 

Quick Links

FLP-Hose
00 - 16ss
Sliver
M16 x 1.5
8.0
15.0
15.0
61.0
28.0
25.0
35
3.0

Out of Stock - Back Order

0

£25.20 Excl VAT
Unit Price: £25.2000
£30.24 Inc VAT
Unit Price: £30.2400

This product is currently out of stock. Your item will be shipped when it is back in stock.

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The FLP Hose Compression Gland is built for flame-proof cable terminations in demanding industrial & underground mining locations. Designed for unarmoured elastomeric and plastic cables, it provides a tight seal to prevent gas or flame migration that is suitable for use in Group I underground mines, Group II, III, Zone 1, 2, 21 and 22 hazardous areas.
The male spigot at the rear allows you to securely attach a flexible protective hose, adding extra shielding for cables exposed to harsh conditions. Precision manufactured from high-quality extruded brass, Marine Grade Electroless Nickel Plated™, this gland offers high resistance to impact, moisture and corrosive atmospheres. Suitable for hazardous areas where flame containment and secure sealing are critical.

 

Key Features

  • For Group I underground mines, Group II, III, Zone 1, 2, 21 and 22 hazardous areas
  • Fitted complete with a specially formulated elastomeric captive seal for Built-in Safety™
  • A hose tail provides for clamping a protective hose over the cable
  • Precision manufactured from extruded brass, Marine Grade Electroless Nickel Plated™
  • Supplied complete with IP sealing washer

 

Technical Details

Equipment Protection Levels:  
IECEx/INMETRO:                Ex db I Mb / Ex eb I Mb / Ex db IIC Gb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da
ATEX/UKEX:                        I M2, II 2/3G 1D, Ex db I Mb / Ex eb I Mb / Ex db IIC Gb / Ex eb IIC Gb, Ex nR IIC Gc,
                                            Ex ta  IIIC Da

Conformance:               Standard:                                       Certification:
IEC/BS EN                     IEC/BS EN 62444, 6121               CML 14CA364 
IECEx                             IEC 60079 Part 0, 1, 7, 15, 31      IECEx TSA 22.0011X
ATEX                              EN 60079 Part 0, 1, 7, 31             CML 16ATEX1001X
                                       EN 60079 Part 0, 15                     CML 16ATEX4002X
UKEX                             BS EN 60079 Part 0, 1, 7, 31        CML 21UKEX1011X
                                      BS EN 60079 Part 0, 15                 CML 21UKEX4006X
Deluge Protection:        DTS-01
Marine:            ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
                         DNV IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
Protection:     IP66 / IP68 (100m - Parallel)  IEC 60529
Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
Material (Gland):  Brass, Marine Grade Electroless Nickel Plated™
Material (Seal):   Standard Thermoset Elastomer or Extreme Temperature Seals

 

Information

Product Type: FLP-Hose

Size: 00 - 16ss

Colour: Sliver

Entry Thread Size: M16 x 1.5

Bedding OD Max (A): 8.0

Cable OD Range Min (B): 15.0

Entry Thread Length (L1): 15.0

Gland Length (L2): 61.0

A/C: 28.0

A/F: 25.0

Torque (Nm): 35

Bedding OD Min (A): 3.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?


If you have spotted a mistake on this page, click the button below and complete the form. Thank you!