The CCG Ex Corrosion Guard Gland Kit is a purpose-built flameproof gland for hazardous environments where corrosion protection and safety are critical. The Corrosion Guard® screws onto the Ex gland body and seals over the outer sheath of the cable giving an IP68 and deluge proof seal protecting the armour and metal parts of the gland.
Designed for maximum ingress protection, it delivers a flameproof, gas tight seal that is suitable for use in Gas Groups II and II , Zones 1, 2, 21 and 22 hazardous areas. 
Each kit up to M32 includes two glands, two locknuts, two earth tags and Corrosion Guard Ex shrouds. M40 and larger come as single kits with locknut and shroud.
This gland includes CCG's patented disconnect system allows for inspection of armour clamp and inner seal after assembly, ensuring reliable earth continuity and mechanical retention of the cable. With CCG’s patented captive component system, the risk of incorrect assembly is reduced, improving site safety and installation reliability.
Manufactured from precision-machined extruded brass Marine Grade Electroless Nickel Plated™, the Ex Corrosion Guard is ideal for use in demanding hazardous areas environments where corrosion protection is critical.

 

Key Features

  • Screw on Corrosion Guard™ shroud, providing total enclosure of SWA and gland body
  • For indoor and outdoor use in hazardous areas
  • Two-part handling
  • Freely rotating captive cone and inspectable cone ring provides an armour clamp and earth bond
  • Seals the cable sheath to IP66 / IP68
  • Patented disconnect system allows for inspection of armour clamp and inner seal after assembly
  • Precision manufactured from extruded brass, Marine Grade Electroless Nickel Plated™
  • Supplied complete with IP sealing washer
  • M16-M32 2 glands, 2 locknuts, 2 earth tags, 2 Corrosion Guard Ex shrouds
  • M40-M100 1 gland, 1 locknut, 1 earth tags, 1 Corrosion Guard Ex shrouds

 

Technical Details

Equipment Protection Levels:  
IECEx/INMETRO:                Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX/UKEX:                        II 2/3 G 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc Ex ta IIIC Da

Conformance:               Standard:                                       Certification:
IEC/BS EN                     IEC/BS EN 62444, 6121               CML 14CA364 
IECEx                             IEC 60079 Part 0, 1, 7, 15, 31      IECEx CML 18.0018X
ATEX                              EN 60079 Part 0, 1, 7, 31             CML 16ATEX1001X
                                       EN 60079 Part 0, 15                     CML 16ATEX4002X
UKEX                             BS EN 60079 Part 0, 1, 7, 31        CML 21UKEX1011X
                                      BS EN 60079 Part 0, 15                 CML 21UKEX4006X
Deluge Protection:        DTS-01
Marine:            ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
                        DNV IEC/EN 60079 Part 0, 1, 7, 15, 31
Protection:     IP66 / IP68 (100m - Parallel)  IEC 60529
Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
Material (Gland):  Brass, Marine Grade Electroless Nickel Plated™
Material (Seal):   Standard Thermoset Elastomer or Extreme Temperature Seals

 

Quick Links

E1EX CG Kits
1 - 20
M20 x 1.5
15.0
14.5
20.5
15.0
66.0
30.0
27.0
0.20
1.3
21
9.0

Out of Stock - Back Order

0

£28.80 Excl VAT
Unit Price: £28.8000
£34.56 Inc VAT
Unit Price: £34.5600

This product is currently out of stock. Your item will be shipped when it is back in stock.

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The CCG Ex Corrosion Guard Gland Kit is a purpose-built flameproof gland for hazardous environments where corrosion protection and safety are critical. The Corrosion Guard® screws onto the Ex gland body and seals over the outer sheath of the cable giving an IP68 and deluge proof seal protecting the armour and metal parts of the gland.
Designed for maximum ingress protection, it delivers a flameproof, gas tight seal that is suitable for use in Gas Groups II and II , Zones 1, 2, 21 and 22 hazardous areas. 
Each kit up to M32 includes two glands, two locknuts, two earth tags and Corrosion Guard Ex shrouds. M40 and larger come as single kits with locknut and shroud.
This gland includes CCG's patented disconnect system allows for inspection of armour clamp and inner seal after assembly, ensuring reliable earth continuity and mechanical retention of the cable. With CCG’s patented captive component system, the risk of incorrect assembly is reduced, improving site safety and installation reliability.
Manufactured from precision-machined extruded brass Marine Grade Electroless Nickel Plated™, the Ex Corrosion Guard is ideal for use in demanding hazardous areas environments where corrosion protection is critical.

 

Key Features

  • Screw on Corrosion Guard™ shroud, providing total enclosure of SWA and gland body
  • For indoor and outdoor use in hazardous areas
  • Two-part handling
  • Freely rotating captive cone and inspectable cone ring provides an armour clamp and earth bond
  • Seals the cable sheath to IP66 / IP68
  • Patented disconnect system allows for inspection of armour clamp and inner seal after assembly
  • Precision manufactured from extruded brass, Marine Grade Electroless Nickel Plated™
  • Supplied complete with IP sealing washer
  • M16-M32 2 glands, 2 locknuts, 2 earth tags, 2 Corrosion Guard Ex shrouds
  • M40-M100 1 gland, 1 locknut, 1 earth tags, 1 Corrosion Guard Ex shrouds

 

Technical Details

Equipment Protection Levels:  
IECEx/INMETRO:                Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX/UKEX:                        II 2/3 G 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc Ex ta IIIC Da

Conformance:               Standard:                                       Certification:
IEC/BS EN                     IEC/BS EN 62444, 6121               CML 14CA364 
IECEx                             IEC 60079 Part 0, 1, 7, 15, 31      IECEx CML 18.0018X
ATEX                              EN 60079 Part 0, 1, 7, 31             CML 16ATEX1001X
                                       EN 60079 Part 0, 15                     CML 16ATEX4002X
UKEX                             BS EN 60079 Part 0, 1, 7, 31        CML 21UKEX1011X
                                      BS EN 60079 Part 0, 15                 CML 21UKEX4006X
Deluge Protection:        DTS-01
Marine:            ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 and IEC 60529
                        DNV IEC/EN 60079 Part 0, 1, 7, 15, 31
Protection:     IP66 / IP68 (100m - Parallel)  IEC 60529
Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
Material (Gland):  Brass, Marine Grade Electroless Nickel Plated™
Material (Seal):   Standard Thermoset Elastomer or Extreme Temperature Seals

 

Information

Product Type: E1EX CG Kits

Size: 1 - 20

Entry Thread Size: M20 x 1.5

Bedding OD Max (A): 15.0

Cable OD Range Min (B): 14.5

Cable OD Range Max (B): 20.5

Entry Thread Length (L1): 15.0

Gland Length (L2): 66.0

A/C: 30.0

A/F: 27.0

Armour Dia Min (F): 0.20

Armour Dia Max (F): 1.3

Torque (Nm): 21

Bedding OD Min (A): 9.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 