054101A-UN - M20 A2F EExde IIC Unplated Compression Gland

SKU: 054101A-UN

054101A-UN - M20 A2F EExde IIC Unplated Compression Gland

The A2F Compression Gland is designed for use with unarmoured, elastomeric and plastic cables in hazardous areas. Incorporating a specially formulated elastomeric displacement seal explosion and flame-proof protection. Provides an increased safety EExde IIC seal on the cable sheath to IP68 if fitted with a sealing washer.

 

  • For indoor and outdoor use in hazardous areas.
  • Seals the cable sheath to IP66 / IP68.
  • Specially formulated elastomeric seal.
  • Wide sealing range.
  • Precision manufactured from high quality brass.
  • Supplied complete with IP sealing washer.

     

    Hazardous: IECEx/INMETRO: Ex db eb I Mb, Ex db eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
    Classification ATEX/UKEX: I M2, II 2/3 G,Ex db eb I Mb, Ex db eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
    Marine: ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 / DNV IEC/EN 60079 Part 0, 1, 7, 15, 31

    Protection: IP66 / IP68 (100m - Parallel) IEC 60529
    Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
    Material (gland): Brass / Marine Grade Electroless Nickel Plated™
    Material (Seal): Standard Thermoset Elastomer or Extreme Temperature Seals

Quick Links

A2F Brass
1 - 20
Brass
M20 x 1.5
11.0
15.0
15.0
45.0
30.0
27.0
33

In stock

102

£6.99 Excl VAT
Unit Price: £6.9900
£8.39 Inc VAT
Unit Price: £8.3880

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The A2F Compression Gland is designed for use with unarmoured, elastomeric and plastic cables in hazardous areas. Incorporating a specially formulated elastomeric displacement seal explosion and flame-proof protection. Provides an increased safety EExde IIC seal on the cable sheath to IP68 if fitted with a sealing washer.

 

  • For indoor and outdoor use in hazardous areas.
  • Seals the cable sheath to IP66 / IP68.
  • Specially formulated elastomeric seal.
  • Wide sealing range.
  • Precision manufactured from high quality brass.
  • Supplied complete with IP sealing washer.

     

    Hazardous: IECEx/INMETRO: Ex db eb I Mb, Ex db eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
    Classification ATEX/UKEX: I M2, II 2/3 G,Ex db eb I Mb, Ex db eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
    Marine: ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 / DNV IEC/EN 60079 Part 0, 1, 7, 15, 31

    Protection: IP66 / IP68 (100m - Parallel) IEC 60529
    Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
    Material (gland): Brass / Marine Grade Electroless Nickel Plated™
    Material (Seal): Standard Thermoset Elastomer or Extreme Temperature Seals

Information

Product Type: A2F Brass

Size: 1 - 20

Colour: Brass

Entry Thread Size: M20 x 1.5

Cable OD Range Min (B): 11.0

Cable OD Range Max (B): 15.0

Entry Thread Length (L1): 15.0

Gland Length (L2): 45.0

A/C: 30.0

A/F: 27.0

Torque (Nm): 33

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?