The CCG A2 Low Smoke Gland Kit is a highly dependable compression gland designed for single and multi-core unarmoured cables in demanding industrial and commercial installations. Precision-engineered from premium nickel-plated brass, it offers exceptional resistance against corrosion while effortlessly handling harsh environments, water ingress, heavy dust, and mechanical impacts.

When properly installed with the supplied high-performance thread sealing washer, the gland achieves superior IP66, IP67, and IP68 ratings for completely secure, watertight cable entry. Its intelligent, advanced design features a displacement seal that grips the outer cable sheath firmly to provide strong retention, all without harming or distorting the delicate inner conductors.

Each kit up to size M32 includes two glands, two locknuts, and two Low Smoke PVC shrouds for an enhanced safety installation solution. Sizes M40 and larger come as single kits containing one gland, locknut, and a Low Smoke PVC shroud.

The CCG A2 Low Smoke Gland Kit is perfectly suited for power, control, and instrumentation applications where robust, long-lasting cable sealing, reliable environmental protection, and enhanced fire safety performance are required in both indoor and outdoor settings.


 

Key Features

  • Seals the cable sheath to IP66 / IP68
  • Nickel-plated brass for corrosion resistance
  • Strong cable retention thanks to specially formulated elastomeric seal
  • Wide clamping range for versatile cable sizes
  • Supplied complete with thread sealing washer
  • Suitable for indoor and outdoor use
  • M16-M32 2 glands, 2 locknuts, 2 PVC LS shrouds
  • M40-M75 1 gland, 1 locknut, 1 PVC LS shrouds


 

Technical Details

Design Standards: BS 6121 Part 1 EN50262 EN 50262 IEC 62444 SANS62444 SANS 1213
Marine: ABS 14-SG246753-2-PDA / DNV-GL TAE000000Z
London Underground Approval: BS EN62444
Protection: IP66 / IP67 / IP68 (2m cont.)
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Seal): Thermoset Elastomer

 

Quick Links

A2 LS Kits
6 - 63
Silver
M63 x 1.5
44.5
56.5
15.0
63.0
90.0
80.0
98

Built To Order

0

£51.99 Excl VAT
Unit Price: £51.9900
£62.39 Inc VAT
Unit Price: £62.3880

This product is currently out of stock. Your item will be shipped when it is back in stock.

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The CCG A2 Low Smoke Gland Kit is a highly dependable compression gland designed for single and multi-core unarmoured cables in demanding industrial and commercial installations. Precision-engineered from premium nickel-plated brass, it offers exceptional resistance against corrosion while effortlessly handling harsh environments, water ingress, heavy dust, and mechanical impacts.

When properly installed with the supplied high-performance thread sealing washer, the gland achieves superior IP66, IP67, and IP68 ratings for completely secure, watertight cable entry. Its intelligent, advanced design features a displacement seal that grips the outer cable sheath firmly to provide strong retention, all without harming or distorting the delicate inner conductors.

Each kit up to size M32 includes two glands, two locknuts, and two Low Smoke PVC shrouds for an enhanced safety installation solution. Sizes M40 and larger come as single kits containing one gland, locknut, and a Low Smoke PVC shroud.

The CCG A2 Low Smoke Gland Kit is perfectly suited for power, control, and instrumentation applications where robust, long-lasting cable sealing, reliable environmental protection, and enhanced fire safety performance are required in both indoor and outdoor settings.


 

Key Features

  • Seals the cable sheath to IP66 / IP68
  • Nickel-plated brass for corrosion resistance
  • Strong cable retention thanks to specially formulated elastomeric seal
  • Wide clamping range for versatile cable sizes
  • Supplied complete with thread sealing washer
  • Suitable for indoor and outdoor use
  • M16-M32 2 glands, 2 locknuts, 2 PVC LS shrouds
  • M40-M75 1 gland, 1 locknut, 1 PVC LS shrouds


 

Technical Details

Design Standards: BS 6121 Part 1 EN50262 EN 50262 IEC 62444 SANS62444 SANS 1213
Marine: ABS 14-SG246753-2-PDA / DNV-GL TAE000000Z
London Underground Approval: BS EN62444
Protection: IP66 / IP67 / IP68 (2m cont.)
Temperature Range: -65°C to 120°C
Material (Gland): Brass (Nickel Plated) BS 2874 / EN 12164
Material (Seal): Thermoset Elastomer

 

Information

Product Type: A2 LS Kits

Size: 6 - 63

Colour: Silver

Entry Thread Size: M63 x 1.5

Cable OD Range Min (B): 44.5

Cable OD Range Max (B): 56.5

Entry Thread Length (L1): 15.0

Gland Length (L2): 63.0

A/C: 90.0

A/F: 80.0

Torque (Nm): 98

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?


If you have spotted a mistake on this page, click the button below and complete the form. Thank you!

Report mistake

 
 

Related products