The ArmaKit® A2 Low Smoke Cable Gland is a dependable brass gland kit designed for weatherproof terminations of all types of unarmoured or braided cables that are terminated within the enclosure. This outdoor-rated cable gland provides a secure seal and reliable cable retention, making it ideal for external panels, junction boxes and equipment where protection from moisture and dust is essential.

The A2 gland includes an internal seal that grips the outer sheath of the cable, blocks water and dirt from entering the enclosure through the cable entry point. 

ArmaKit® A2 glands are made from robust extruded to maintain long-lasting performance in harsh conditions. Each kit includes a low smoke shroud and locknut for a safe, tidy installation.

 

Key Features

  • Brass gland for unarmoured, elastometric cables
  • For indoor and outdoor use
  • Seals on cable sheath to IP66 if fitted with a sealing washer
  • Low smoke shroud reduces fumes in fire
  • M16-M32 2 glands, 2 locknuts, 2 LS shrouds
  • M40-M75 1 gland, 1 locknut, 1 LS shrouds

 

Technical Details

Standards: EN 50262:1998, BS 6121-1:2005
Protection: IP54 IP66 (If fitted with sealing washer)
Temperature Range: -20°C to 80°C
Material (Gland): Brass BS 2874 CZ121 Pb3
Material (Shroud): LS Polyvinyl-chloride

 

Quick Links

A2 ArmaKit
Brass
M20 x 1.5
8.0
11.8
12.0
32.0
24.4
22.0
10.0
120.0

In stock

188

£4.20 Excl VAT
Unit Price: £4.2000
£5.04 Inc VAT
Unit Price: £5.0400

Qty
Minimum Order Qty 1
Increments 1

Product Wishlist & Compare Placeholder

Delivery available from £8.50

Available to select at checkout.

 

Quick Links

 
 

The ArmaKit® A2 Low Smoke Cable Gland is a dependable brass gland kit designed for weatherproof terminations of all types of unarmoured or braided cables that are terminated within the enclosure. This outdoor-rated cable gland provides a secure seal and reliable cable retention, making it ideal for external panels, junction boxes and equipment where protection from moisture and dust is essential.

The A2 gland includes an internal seal that grips the outer sheath of the cable, blocks water and dirt from entering the enclosure through the cable entry point. 

ArmaKit® A2 glands are made from robust extruded to maintain long-lasting performance in harsh conditions. Each kit includes a low smoke shroud and locknut for a safe, tidy installation.

 

Key Features

  • Brass gland for unarmoured, elastometric cables
  • For indoor and outdoor use
  • Seals on cable sheath to IP66 if fitted with a sealing washer
  • Low smoke shroud reduces fumes in fire
  • M16-M32 2 glands, 2 locknuts, 2 LS shrouds
  • M40-M75 1 gland, 1 locknut, 1 LS shrouds

 

Technical Details

Standards: EN 50262:1998, BS 6121-1:2005
Protection: IP54 IP66 (If fitted with sealing washer)
Temperature Range: -20°C to 80°C
Material (Gland): Brass BS 2874 CZ121 Pb3
Material (Shroud): LS Polyvinyl-chloride

 

Information

Product Type: A2 ArmaKit

Colour: Brass

Entry Thread Size: M20 x 1.5

Cable OD Range Min (B): 8.0

Cable OD Range Max (B): 11.8

Entry Thread Length (L1): 12.0

Gland Length (L2): 32.0

A/C: 24.4

A/F: 22.0

Box Qty: 10.0

Carton Qty: 120.0

Accessories

You might also need the following;


Explore Remora’s extensive range of cable gland accessories, including locknuts, earth tags, sealing washers, serrated lock washers, shrouds, earth locknuts, reducers, adaptors, stopping plugs, and breather drain plugs. Everything needed for secure, compliant cable gland installations.

Questions & Answers


Single and double compression cable glands differ in their sealing and clamping mechanisms:

Single Compression Glands: These glands provide compression around the outer sheath of the cable, offering basic sealing and strain relief. They are suitable for indoor/outdoor applications where environmental conditions are controlled.

Double Compression Glands: These glands provide compression at both the outer sheath and the inner bedding layer of the cable. This dual compression offers enhanced sealing and strain relief, making them ideal for outdoor or hazardous environments where additional protection is required.

Yes - Specific types of cable glands are designed for use in hazardous area environments. These glands are constructed to prevent the ingress of flammable gases or dust and are often certified to standards such as ATEX or IECEx, ensuring safety in explosive atmospheres. See CCG Hazardous Area Glands for our full range.

When installing Cable Glands using plain holes and locknuts, the recommended clearance of +0.2 mm above the nominal thread diameter. For example, an M20 gland should be mounted in a 20.2 mm diameter hole. The maximum recommended clearance is +0.7 mm. This ensures a secure fit while allowing easy installation.

 

Spotted a Mistake?


If you have spotted a mistake on this page, click the button below and complete the form. Thank you!

Report mistake

 
 

Related products